Home » Cleanroom Equipment » Bio Safety Cabinets » Biological Safety Cabinet Class 2
Biological Safety Cabinet Class 2
₹ 1,45,000 Get Latest Price
Product Specifications
| Brand | Weiber |
| Illumination Level | 800 |
| Cabinet Construction | Stainless steel / PCRC Powder Coated Sheet |
| Cleanliness Class | ISO class 3 |
| Operating Temperature | 10-50 deg C |
| Operating Relative Humidity | 95% (25 deg C) |
| Atmospheric Pressure | 120 Pa |
| Noise Pressure | 65 db |
| Air Supply Filter | Washable |
| Differential Pressure Indicating Range | 0-500 |
| Differential Pressure Indicating Precision | +-1% |
| Power Requirements | 500-750 watts |
GST No - 06AAKCA8493Q1ZQ | Member since 2023
PLOT NO.126, PHASE-IV, SECTOR 56, KUNDLI, Sonipat, Haryana, 131028
Looking for the latest Biological Safety Cabinet Class 2 price in Sonipat? WEIBER, one of Sonipat's best Biological Safety Cabinet Class 2 sellers & manufacturers, offers a wide range of Biological Read More...
Product Details
WEIBER Biological Safety Cabinet Class II is an open-front, ventilated cabinet. This cabinet provides a HEPA/ULPA-filtered, recirculated mass airflow within the work space. The exhaust air from the cabinet is also filtered by HEPA/ULPA filters. Thus, the Class II biosafety cabinet will provide personnel, environment and product protection. While HEPA/ULPA filters are effective for trapping particulates and infectious agents, these filters will not capture volatile chemicals or gases
The use of a Biological Safety Cabinet Class 2 in the microbiological laboratory offers the additional capability and advantage of protecting materials contained within it from extraneous airborne contaminants. This capability is provided by the HEPA-filtered, recirculated mass airflow within the workspace.
It is suitable for the containment of biohazardous materials and unlike the Class I biosafety cabinet, it is also suitable as a sterile environment for cell cultures.
Classifications:
It is classified in 4 categories:
Class II, type A1: this does not have to be vented, which makes it suitable for use in laboratory rooms which cannot be ducted. This cabinet is acceptable for use of low to moderate risk agents in the absence of volatile toxic chemicals and volatile radionuclides.
Type A, has a minimum inflow velocity of 75 ft/min. The filtered makeup air is divided equally over the work surface at about two to six inches above the work surface. Exhaust is drawn at the bottom of the cabinet where it rises to the top. At the top of the cabinet, 70% of the air recirculates through the supply HEPA filter, the other 30% of air exhausted through the exhaust HEPA/ULPA filter.
This type is not safe for work with hazardous chemicals except when ducted, usually with a "thimble" or canopy hood to avoid disturbing internal air flow.
Class II, type A2: this must be vented. 70% of the air is exhausted from the cabinet while 30% is recirculated. This cabinet may be used with etiologic agents treated with minute quantities of toxic chemicals and trace quantities of radionuclides that will not interfere with work if recirculated in the down flow air.
The Type A2 cabinet, has a minimum inflow velocity of 100 ft/min. A negative air pressure plenum surrounds all contaminated plenums that are under positive pressure. In other respects, the specifications are identical to those of a Type A1 cabinet.
Class II, type B1: this cabinet must be vented, with 30% of the air exhausted from the cabinet while 70% is recirculated back into the room. This cabinet may be used with etiologic agents treated with minute quantities of toxic chemicals and trace amounts of radionuclides required as an adjunct to microbiological studies if work is done in the directly exhausted portion of the cabinet, or if the chemicals or radionuclides will not interfere with the work when recirculated in the down flow air.
The Type B1 cabinets have a minimum inflow velocity of 100 ft/min
Class II, type B2:
this cabinet must be totally exhausted, with100% of the air exhausted through a dedicated duct. This cabinet may be used with etiologic agents treated with toxic chemicals and radionuclides required as an adjunct to microbiological studies.
The Type B1 cabinets have a minimum inflow velocity of 100 ft/min.
PLOT NO.126, PHASE-IV, SECTOR 56, KUNDLI, Sonipat, Haryana, 131028
Send your enquiry to supplier
Related Products
Biosafety Cabinet Class II Type A2
₹ 45,000
| Air Flow : Unidirectional |
| Blower Assembly : Centrifugal lubricated bearing type ISI marked assembly |
| Frequency : 50 Hz Single Phase |
| HEPA Filters : Glass pleated non woven fabric filter having 99.97% efficiency 0.3 micro particles size. |
₹ 82,000
| Air Flow Direction : Horizontal |
| Availability : In Stock |
| Biosafety Level : BSL 1, BSL 2, BSL 3 |
| Brand : Esporti l |
Mild Steel Bio Safety Cabinet, For Laboratory
₹ 1,25,000
| Color : Silver |
| Country of Origin : Made in India |
| Frequency : 50 Hz |
| Material : Mild Steel |
Mild Steel Biosafety Cabinet, For Laboratory, 48 wells
₹ 55,000
| Brand : Lasin |
| Class : Class II |
| Frequency : 50 Hz |
| Product Type : Type B2 |
₹ 30,000
| Model : Bio-Safety Cabinet |
Ultra Violet Light Stainless Steel Bio Safety Cabinet
₹ 1,80,000
| Availability : In Stock |
| Brand : Accumax |
| Efficiency (%) : 99.99 |
| Front Door : Sliding Door Plexiglass |
220V High Quality Biosafety Cabinet Class II Type A2, For Laboratory
₹ 82,000
| Air Flow Direction : Vertical |
| Availability : In Stock |
| Biosafety Level : BSL 2 |
| Brand : INNOLAB |
₹ 1,10,000
| Air Flow : Vertical |
| Material : Stainless Steel |
| Model Number : PBSC-22 |
| Model : Biosafety Cabinets |
Steel Justrite Fireproof Safety Cabinet, For Chemical/ Flammable Storage
₹ 40,000
| Application : Chemical/ Flammable Storage |
| Brand : Justrite |
| Dimensions (mm) : 1651H x 1092W x 457D mm |
| Features : Fire-Resistant |
Customer Reviews
Submit your Reviews
Best Selling Products from Weiber
₹ 75,000
| Brand : Weiber |
| Console Operating Temperature : +14 deg to +140 deg F (-10 deg to +60 deg C) |
| Display Temperature : +32 deg to +140 deg F (0 deg to +60 deg C) |
| Housing Material : UV-resistant ABS plastic |
₹ 2,95,000
| Brand : Weiber |
| Construction : Stainless Steel |
| Temperature Tolerance : +/- 1 deg. C |
| Working Temperature : -20 deg. C |
₹ 2,50,000
| Brand : Weiber |
| Construction : Stainless steel |
| Temperature Tolerance : +/- 1 deg. C |
| Working Temperature : -40 deg. C |
Weiber 0 deg C Walkin Cold Room
₹ 3,32,000
| Brand : Weiber |
| Construction : Stainless Steel |
| Temperature Tolerance : +/- 1 deg. C |
| Working Temperature : 0 deg. C |
₹ 40,00,000
| Body Material : GI |
| Insulation Thickness : 100 millimeter |
| Size : 34" to 40" (W) x72" to 80" (H) |
| Storage Capacity (in Ton) : 16.5 |
₹ 5,65,000
| Brand : Weiber |
| Construction : Stainless Steel |
| Temperature Control : Digital Temperature Controller |
| Working Temperature : -60 deg. C |
Aluminium Weiber Blast Freezer
₹ 1,00,000
| Accuracy : +-1 deg C |
| Body Material : Aluminium |
| Brand : Weiber |
| Temperature Range : -80deg C to -2 deg C |
Weiber Industrial Freeze Dryer Industrial Lyophilizer
₹ 85,000
| Brand : Weiber |
| Compressor : 1/3 HP (hermetically sealed) |
| Display : LCD |
| Temperature : -35 deg C to -80 deg C |
Weiber Pilot Scale Freeze Dryer
₹ 72,000
| Brand : Weiber |
| Compressor : 1/3 HP (hermetically sealed) |
| Display : LCD |
| Temperature : -35 deg C to -80 deg C |
₹ 98,000
| Brand : Weiber |
| Frequency : 50 Hz |
| Outer Construction : SS 304/PCRC |
| Temperature Range : -25 deg C to 150 deg C (Standard) |
