Home » Cleanroom Equipment » Bio Safety Cabinets » Biological Safety Cabinet Class 2

Biological Safety Cabinet Class 2
Biological Safety Cabinet Class 2

Biological Safety Cabinet Class 2

₹ 1,45,000 Get Latest Price

Product Specifications

Brand Weiber
Illumination Level 800
Cabinet Construction Stainless steel / PCRC Powder Coated Sheet
Cleanliness Class ISO class 3
Operating Temperature 10-50 deg C
Operating Relative Humidity 95% (25 deg C)
Atmospheric Pressure 120 Pa
Noise Pressure 65 db
Air Supply Filter Washable
Differential Pressure Indicating Range 0-500
Differential Pressure Indicating Precision +-1%
Power Requirements 500-750 watts

GST No - 06AAKCA8493Q1ZQ | Member since 2023

PLOT NO.126, PHASE-IV, SECTOR 56, KUNDLI, Sonipat, Haryana, 131028

Looking for the latest Biological Safety Cabinet Class 2 price in Sonipat? WEIBER, one of Sonipat's best Biological Safety Cabinet Class 2 sellers & manufacturers, offers a wide range of Biological Read More...

   Qty  

Product Details

WEIBER Biological Safety Cabinet Class II is an open-front, ventilated cabinet. This cabinet provides a HEPA/ULPA-filtered, recirculated mass airflow within the work space. The exhaust air from the cabinet is also filtered by HEPA/ULPA filters. Thus, the Class II biosafety cabinet will provide personnel, environment and product protection. While HEPA/ULPA filters are effective for trapping particulates and infectious agents, these filters will not capture volatile chemicals or gases

The use of a Biological Safety Cabinet Class 2 in the microbiological laboratory offers the additional capability and advantage of protecting materials contained within it from extraneous airborne contaminants. This capability is provided by the HEPA-filtered, recirculated mass airflow within the workspace.

It is suitable for the containment of biohazardous materials and unlike the Class I biosafety cabinet, it is also suitable as a sterile environment for cell cultures.

Classifications:

It is classified in 4 categories:

Class II, type A1: this does not have to be vented, which makes it suitable for use in laboratory rooms which cannot be ducted. This cabinet is acceptable for use of low to moderate risk agents in the absence of volatile toxic chemicals and volatile radionuclides.


Type A, has a minimum inflow velocity of 75 ft/min. The filtered makeup air is divided equally over the work surface at about two to six inches above the work surface. Exhaust is drawn at the bottom of the cabinet where it rises to the top. At the top of the cabinet, 70% of the air recirculates through the supply HEPA filter, the other 30% of air exhausted through the exhaust HEPA/ULPA filter.


This type is not safe for work with hazardous chemicals except when ducted, usually with a "thimble" or canopy hood to avoid disturbing internal air flow.


Class II, type A2: this must be vented. 70% of the air is exhausted from the cabinet while 30% is recirculated. This cabinet may be used with etiologic agents treated with minute quantities of toxic chemicals and trace quantities of radionuclides that will not interfere with work if recirculated in the down flow air.


The Type A2 cabinet, has a minimum inflow velocity of 100 ft/min. A negative air pressure plenum surrounds all contaminated plenums that are under positive pressure. In other respects, the specifications are identical to those of a Type A1 cabinet.


Class II, type B1: this cabinet must be vented, with 30% of the air exhausted from the cabinet while 70% is recirculated back into the room. This cabinet may be used with etiologic agents treated with minute quantities of toxic chemicals and trace amounts of radionuclides required as an adjunct to microbiological studies if work is done in the directly exhausted portion of the cabinet, or if the chemicals or radionuclides will not interfere with the work when recirculated in the down flow air.


The Type B1 cabinets have a minimum inflow velocity of 100 ft/min


Class II, type B2: this cabinet must be totally exhausted, with100% of the air exhausted through a dedicated duct. This cabinet may be used with etiologic agents treated with toxic chemicals and radionuclides required as an adjunct to microbiological studies.
The Type B1 cabinets have a minimum inflow velocity of 100 ft/min.


Weiber Logo
   Weiber

PLOT NO.126, PHASE-IV, SECTOR 56, KUNDLI, Sonipat, Haryana, 131028

Send your enquiry to supplier

s

Related Products

Biosafety Cabinet Class II Type A2

₹ 45,000

Air Flow : Unidirectional
Blower Assembly : Centrifugal lubricated bearing type ISI marked assembly
Frequency : 50 Hz Single Phase
HEPA Filters : Glass pleated non woven fabric filter having 99.97% efficiency 0.3 micro particles size.

Labsol Enterprises,

Biosafety Cabinet, Class II

₹ 82,000

Air Flow Direction : Horizontal
Availability : In Stock
Biosafety Level : BSL 1, BSL 2, BSL 3
Brand : Esporti l

Esporti Impex, Chandigarh

Mild Steel Bio Safety Cabinet, For Laboratory

₹ 1,25,000

Color : Silver
Country of Origin : Made in India
Frequency : 50 Hz
Material : Mild Steel

Airz Tech Solutions, Palghar, Maharashtra

Mild Steel Biosafety Cabinet, For Laboratory, 48 wells

₹ 55,000

Brand : Lasin
Class : Class II
Frequency : 50 Hz
Product Type : Type B2

Labsoul (india), Ambala, Haryana

Ultra Violet Light Stainless Steel Bio Safety Cabinet

₹ 1,80,000

Availability : In Stock
Brand : Accumax
Efficiency (%) : 99.99
Front Door : Sliding Door Plexiglass

ACCUMAX INDIA, New Delhi, Delhi

220V High Quality Biosafety Cabinet Class II Type A2, For Laboratory

₹ 82,000

Air Flow Direction : Vertical
Availability : In Stock
Biosafety Level : BSL 2
Brand : INNOLAB

Innolab Instruments, North West Delhi, Delhi

Bio Safety Cabinets

₹ 1,10,000

Air Flow : Vertical
Material : Stainless Steel
Model Number : PBSC-22
Model : Biosafety Cabinets

Protech Air Systems Private Limited,

Steel Justrite Fireproof Safety Cabinet, For Chemical/ Flammable Storage

₹ 40,000

Application : Chemical/ Flammable Storage
Brand : Justrite
Dimensions (mm) : 1651H x 1092W x 457D mm
Features : Fire-Resistant

Pratech Enterprise, Kolkata, West Bengal

Customer Reviews

Submit your Reviews

Best Selling Products from Weiber

Weiber Weather Station

₹ 75,000

Brand : Weiber
Console Operating Temperature : +14 deg to +140 deg F (-10 deg to +60 deg C)
Display Temperature : +32 deg to +140 deg F (0 deg to +60 deg C)
Housing Material : UV-resistant ABS plastic

Weiber Walk In Freezer

₹ 2,95,000

Brand : Weiber
Construction : Stainless Steel
Temperature Tolerance : +/- 1 deg. C
Working Temperature : -20 deg. C

Weiber Cold Storage Room

₹ 2,50,000

Brand : Weiber
Construction : Stainless steel
Temperature Tolerance : +/- 1 deg. C
Working Temperature : -40 deg. C

Weiber 0 deg C Walkin Cold Room

₹ 3,32,000

Brand : Weiber
Construction : Stainless Steel
Temperature Tolerance : +/- 1 deg. C
Working Temperature : 0 deg. C

16.5 Weiber Walk In Cooler

₹ 40,00,000

Body Material : GI
Insulation Thickness : 100 millimeter
Size : 34" to 40" (W) x72" to 80" (H)
Storage Capacity (in Ton) : 16.5

Weiber Industrial Cold Room

₹ 5,65,000

Brand : Weiber
Construction : Stainless Steel
Temperature Control : Digital Temperature Controller
Working Temperature : -60 deg. C

Aluminium Weiber Blast Freezer

₹ 1,00,000

Accuracy : +-1 deg C
Body Material : Aluminium
Brand : Weiber
Temperature Range : -80deg C to -2 deg C

Weiber Industrial Freeze Dryer Industrial Lyophilizer

₹ 85,000

Brand : Weiber
Compressor : 1/3 HP (hermetically sealed)
Display : LCD
Temperature : -35 deg C to -80 deg C

Weiber Pilot Scale Freeze Dryer

₹ 72,000

Brand : Weiber
Compressor : 1/3 HP (hermetically sealed)
Display : LCD
Temperature : -35 deg C to -80 deg C

Weiber Recirculatory Chiller

₹ 98,000

Brand : Weiber
Frequency : 50 Hz
Outer Construction : SS 304/PCRC
Temperature Range : -25 deg C to 150 deg C (Standard)

Ask a Question

Find Best Price for