Home » Switches & Switch Boxes » Level Switches » Kabir RF Admittance Point Level Switches, RFLS-108
Kabir RF Admittance Point Level Switches, RFLS-108
₹ 18,900 Get Latest Price
Product Specifications
| Brand | kabir |
| Usage/Application | LIQUID OR POWDER |
| Size | UP TO 2 MTR |
| Brand | Kabir |
| Current Rating (Amps) | 24 VDC OR 230 VAC |
| Media Type | Liquid |
| Model No. | RFLS-108 |
GST No - 24AANFK0752A1ZS | Member since 2026
PLOT NO.274, G I D C STATE, MAKARPURA, Vadodara, Gujarat, 390010
Kabir RF Admittance Point Level Switches, RFLS-108 Read More...
Product Details
We are Manufacturer of rd level switch and its parts Housing : Aluminium, weatherproof IP 67, powder coated , integral with the probe mounting Cable Entry : 1 no.s (standard) Ambinent temperate : 0 Power consumption : 0.15 W Mains Voltage : 18 to30 VDC Output : PNP NO/NC Operating Frequency : 6 KHz COAT GUARD SENSING PROBE: Mounting : Screwed BSP (standard) Or Flanged (optional) or as per specification. Sense rod : Stainless steel Shield : Stainless steel Insulation : PTFE (standard)Other on request and as per application. Operating Temp in :100 deg for the integral switching vessel unit. For higher temp remote switching unit(please consult works) THEORY: The RF level switch operates on the basis of RF absorption measurement. The electronic unit generates a sinusoidal wave, applied to the electrode creating a field around it. RF environment absorption changes (electrical loss) around the electrode are reflected on changes of generator supply current. Such changes, caused by the increase in level is amplified and used to energies the relay. The main drawback of the conventional method is that after the level has once increased and then decreased, there may be a coating left on the probe which is sensed by the instrument as though the level is still on the probe. In KABIRADMIT a COAT GUARD and Trance Conductance amplifier are incorporated in the circuit having its output exactly at the same voltage and phase at all times as its input. The output is connected through the shield of the low capacitance co-axial cable to the concentric tube on the sense probe, called shield element. Since both the elements, sense and shield are exactly at the same potential and phase at all times, there is no current flow through the cable. Thus there is no change in calibration due to coating on the probe and the temperature effect of the cable.FeaturesLevel Switches/SensorRF Admittance Level Switches/Sensor
PLOT NO.274, G I D C STATE, MAKARPURA, Vadodara, Gujarat, 390010
Send your enquiry to supplier
Related Products
5 Amps Relay Omron Floatess Level Switch 61F-GP-N2, Media Type: Liquid, 10
₹ 4,150
| Country of Origin : Made in India |
| Current Rating : 5 AMPS |
| Measuring Range : POWER |
| Media Type : Liquid |
Magicpack Automations Private Limited, Medchal Malkajgiri, Telangana
Top Mounted Liquid Level Switch, Pole And Throw Specification: SPST, Upto 10bar
₹ 4,500
| Country of Origin : Made in India |
| Media Type : Liquid |
| Mounting Options : Top Mount |
| Pole And Throw Specification : SPST |
Sapcon Ultrasonic Level Switch
₹ 4,500
| Accuracy : +-0.5% |
| Brand : Sapcon |
| Display : Multiline LCD |
| Ingress Protection : IP65 |
Magnetic Engler Liquid Level Switch, Supply voltage: 24V DC, Output type: Continuous analogue output
₹ 21,000
| Availability : In Stock |
| Brand : Engler |
| Connection : plug-type connector M12x1, 4-pole, material TPU on alu housing 27mm |
| Current Rating : IP 65 |
VIPL-DLS-05 Displacer Type Level Switch
₹ 8,000
| Differentia : Max 70mm in S.G 1 |
| Electric Connection : NPT |
| Min. Process Connection : 3" flanged standard in MS/SS304/SS316/polypropylene |
| Temperature : A) SS & Teflon displacers 1500C |
Micro Switch Side Mount LA-A-215A-D-A-1-D02, Measuring Range: 18 Kg, Media Type: Liquid
₹ 4,777
| Availability : In Stock |
| Brand : Baumer |
| Material/Body : Metal |
| Measuring Range : 18 kg |
Float Liquid Mini Level Switches, Switch rating: 1A 230V AC
₹ 2,000
| Material : Stainless Steel |
| Process temperature : 0 to 120 C |
| Sensing principle : Float |
| Supply voltage : 12-24V DC |
₹ 3,690
| Mounting Options : Side Mount |
Media Type: Liquid Side Mounted Switches
₹ 3,330
| Cable Entry : 1/2" |
| Insertion length : 200 MM |
| Lead Wire : 3 |
| Material : Stainless Steel |
Boiler / Water Level Switch NRS 1 -7B, 230 V AC
₹ 90,000
| Level Measurement Type : Continuous Level |
| Media Type : Liquid |
| Model Number : NRS 1-7B |
| Recommended Order Quantity : 1 Piece |
Customer Reviews
Submit your Reviews
Best Selling Products from KABIR INSTRUMENTS AND TECHNOLOGY
₹ 900
| Availability : In Stock |
| Brand : pi |
| Brand : Pi Controls |
| Dial Size : DN50/ DN63 / DN80 / DN100 |
PI Burdon Tube Electric Contact Type Pressure Gauge, For Industrial, Model Name/Number: PG-09
₹ 5,400
| Brand : PI |
| Color : ss |
| Connection : Bottom Connection |
| Dial Size : DN100 / DN150 |
Electromagnetic Water Flow Meter, Emf
₹ 27,900
| Accuracy : 1% |
| Application Media : Water |
| Brand : ABB |
| Flow range : 0-320 |
Float And Board Level Indicator
₹ 8,550
| Material : Metal |
| Measuring Range : 0-30 mtr |
| Media Type : Liquid |
| Mounting Options : Top Mount |
₹ 10,800
| Application : Laboratory |
| Country of Origin : Made in India |
| Fluid Type : Oil |
| Material : Stainless Steel |
₹ 6,300
| Connections : Flanged OR Screwed OR Triclover Joint or Hose Nipple |
| Enclosure : IP 55 or IP 65 on request |
| Range Ability : 20000 LPH |
| Scale length : 220 mm |
Acrylic Body Rotameter For Water Treatment, For Gas
₹ 1,350
| Accuracy : 4% |
| Application : Water Treatment |
| Country of Origin : Made in India |
| Pressure : 1 mpa |
₹ 6,300
| Accuracy : + 2% of Full Scale |
| Application : Industrial |
| Float : SS-316 |
| Indicator Housing : Aluminum/ABS |
Glass Rotameter with Sensor, For Industrial Use, 100 LPH
₹ 14,400
| Accessories : Hi- low flow switch control valve |
| Accuracy : +- 5% of full scale |
| Pressure Rating : 10 Bar |
| Range Ability : 100 LPH |
Glass Tube Rotameter, GTRM-009
₹ 10,800
| Accessories : Screwed /Flanged House -connection |
| Accuracy : +/-1.5 % full scale reading |
| Flow range : 10 to 20,000 LPH of water |
| Line Size : 15 mm NB to 100 NB |
