Home » Lab Instrument » Abel Flash Point Apparatus » LALCO IP standard Abel''s Flash Point Apparatus, For Oil And Petroleum, Model Name/Number: 810

LALCO IP standard Abel''s Flash Point Apparatus, For Oil And Petroleum, Model Name/Number: 810

LALCO IP standard Abel''s Flash Point Apparatus, For Oil And Petroleum, Model Name/Number: 810

₹ 13,500 Get Latest Price

Product Specifications

Brand LALCO
Usage/Application Oil and Petroleum
Material IP standard
Availability In Stock
Brand LALCO
Capacity Standard
IIC-436 Electric heated with oil test jet or Gas test jet without any control.
IIC-436A Electric heated with oil test jet or Gas test jet with separate energy regulator control.
IIC-436B -do -do- concealed Hot Plate.
IIC-437A Electric heated with voltage varric coper coil type.
IIC-437AA Electric heated by concealed Hot Plate with voltage varric copper coil type as per IIC-437A.
IIC-475 Abel's Flash Point Apparatus temperature range-200C+700C with refrigeration system as per IP 170 with oil test jet/Gas test jet device.
IIC-476 Same as IIC-437A. Temp. is controlled by digital temperature controller cum indicator.
IIC-552 Gas heated with oil test jet or Gas test jet without burner.
Model Name/Number 810
Shape as per IP
Temperature Range Flash Point below 70C

GST No - 24AREPP4074G1ZT | Member since 2026

B-12, Satyam Industrial Estate, B/H. ZYDUS RESEARCH CENTER, OPP.SARVOTTAM HOTEL, MORAIYA, Changodar, Ahmedabad, Gujarat, 382213

LALCO IP standard Abel''s Flash Point Apparatus, For Oil And Petroleum, Model Name/Number: 810 Read More...

   Qty  

Product Details

"LALCO" ABEL'S FLASH POINT APPARATUS.[IP 33, 170,IS-1448]- Used for determining of the closed cup Flash point of Petroleum Products,their mixtures, others liquids & Paints having Flash Point below 70C. The apparatus consists of one brass cupand cover fitted with shutter mechanism test flame arrangement(Oil test jet or Gas test jet) and stirrer, placed on a water bath made of Stainless Steel double walled. The outer jecket of the water bath is fitted with a stand. For electrically heated apparatus,heater is fitted to the stand the heat of which may be controlled different temperature regulation system of operated on 220 Volts AC mains. For Gas heated model the drum is heated by a burner.(without burner).     Optional Accessories: IIC-475 Abel's Flash Point Apparatus temperature range-200C+700C with refrigeration system as per IP 170 with oil test jet/Gas test jet device. IIC-552 Gas heated with oil test jet or Gas test jet without burner. IIC-436 Electric heated with oil test jet or Gas test jet without any control. IIC-436A Electric heated with oil test jet or Gas test jet with separate energy regulator control. IIC-436B -do -do- concealed Hot Plate. IIC-437A Electric heated with voltage varric coper coil type. IIC-437AA Electric heated by concealed Hot Plate with voltage varric copper coil type as per IIC-437A. IIC-476 Same as IIC-437A. Temp. is controlled by digital temperature controller cum indicator.

D.P.LAB INSTRUMENTS Logo
   D.P.LAB INSTRUMENTS

B-12, Satyam Industrial Estate, B/H. ZYDUS RESEARCH CENTER, OPP.SARVOTTAM HOTEL, MORAIYA, Changodar, Ahmedabad, Gujarat, 382213

Send your enquiry to supplier

s

Related Products

Abels Flash Point Apparatus

₹ 15,000

Brand : EIE
Country of Origin : Made in India
Frequency : 50-60 Hz
Power Source : Electric

Alfa Engineering Solutions, Thane, Maharashtra

ABELS FLASH Point APPARATUS

₹ 9,000

Automation Type : Automatic
Country of Origin : Made in India
Delivery Time : 1-2 Weeks
Item Code : SSE-04

Sunshine Scientific Equipments,

Abel''s Flash Point Apparatus

₹ 6,300

Application : Laboratory
Brand : Lasin
Finish : Powder Coated
Frequency : 50 Hz

Labsoul (india), Ambala, Haryana

80 Degree C Flash Point Testing Apparatus

₹ 10,500

Material : Mild Steel
Operating Voltage : 230V
Phase : Single Phase
Rated Power : 1900W

Labbazaar India Private Limited, Bengaluru, Karnataka

Pensky Marten Open Or Closed Cup Flash Point Tester

₹ 2,80,000

Availability : In Stock
Cup Type : Closed Cup
Display Type : Digital
Flash Point Range : 0 to 400°C

Haico India, Thane, Tamil Nadu

BRASS Flash & Fire Point Apparatus, For Bitumen Testing

₹ 18,000

Automation Type : HAND OPERATE
Brand : BBN SCIENTIFIC
Color : TATA BLUE
Country of Origin : Made in India

B.b.n. Scientific, New Delhi, Delhi

Customer Reviews

Submit your Reviews

Best Selling Products from D.P.LAB INSTRUMENTS

White And Black Single Wall UV Sterilizer Cabinet, Automation Grade: Manual, Model: LALCO

₹ 15,000

Approval Certificate : ISO 9001 2008
Automation Grade : Manual
Availability : In Stock
Color : White And Black

Single Stage Vacuum Pump

₹ 20,000

Availability : In Stock
Capacity : 32 TO 100 Ltr/Min.
Mounting : Bench-top, Portable
Number of Stages : Single stage, Double Stage

Single Stage Vacuum Pump

₹ 9,000

Availability : In Stock
Number of Stages : Single stage, Double Stage
Power : max vacuum 5 Pa.
Type : Belt Drive Rotary Vane Pumps, Oil Lubricant Vacuum Pumps, Diaphragm Vacuum Pumps

Laminar Air Flow Cabinet

₹ 55,000

Availability : In Stock
Cleanroom Class : iso
Filter Type : Pre Filter, HEPA
Illumination : Fluorescent

Automatic Polarimeter, 308, for Industrial

₹ 2,50,000

Application : Industrial, Laboratory
Availability : In Stock
Color : Cream
Display Type : Digital

Laboratory Microscope

₹ 8,000

Autoclavable : Yes
Availability : In Stock
Capacity : 1
Class : General Grade

Pensky Martens Flash Point Apparatus

₹ 12,000

Availability : In Stock
Cup Material : Brass
Display Type : Analog
Heating Source : Electric

Remi High Speed Homogenizer And Emulsifiers, Capacity: Standard

₹ 16,500

Availability : In Stock
Capacity : Standard
Model Name/Number : Remi

Laboratory Stirrer

₹ 8,000

Availability : In Stock
Display Type : Digital
Power Source : Electric

Ask a Question

Find Best Price for