Home » Electronics Components and Supplies » Thyristor Power Regulator » Single Phase JU Series Single-Phase Thyristor Regulator

Single Phase JU Series Single-Phase Thyristor Regulator
Single Phase JU Series Single-Phase Thyristor Regulator

Single Phase JU Series Single-Phase Thyristor Regulator

₹ 6,000 Get Latest Price

Product Specifications

Input signal Selectable on terminals of 4 to 20mADC
Availability In Stock
Rated voltage 100, 110, 120, 200, 220, 240, 380, 400, 440VAC (to be specified)
Output control system Phase-angle firing/zero-cross firing (selectable depended on models)
Rated frequency 50/60Hz (automatic change)
Applicable load Resistive load, inductive load (primary side control of transformer, phase-angle firing system only)
Working temperature range -10 to 55 degree C (0 to 50 degree C for performance guarantee)
Rated current 10, 20, 30, 50, 75, 100, 150, 200, 250, 300, 400, 500, 750, 1000A (to be specified)
Minimum load current 0.5A or more (at 98% output of rated voltage)
Cooling system Natural cooling for 150A or less of rated current Built-in cooling fan for 200A or more
Phase Single Phase
Over current protection Thyristor gate-off (120% or more of rated current, on built-in or external CT)
Allowable frequency fluctuation +/-2Hz of rated frequency (+/- 1Hz for performance guarantee)
Output range 0 to 98% of rated voltage

GST No - 36ADKPN4610N1Z8 | Member since 2026

Fno.B-313, Pno.1 and 7, Ace Ajanta Aprt, Fathullaguda, Rangareddy, Telangana, 500068

Single Phase JU Series Single-Phase Thyristor Regulator Read More...

   Qty  

Product Details

Our company has created a niche in the field of offering JU Series Single-Phase Thyristor Regulator.Features: Compact structureCompact, lightweight and high panel installation densityOptionsThe options of heater disconnection alarm function and current limit function are available.Phase-angle firing/zero-cross firingThe phase-angle firing system and the zero-cross firing system are selectable. The running by the phase-angle firing system at the initial stage and by the zero-cross firing system at the normal stage is possible.Zero-cross firing systemWith the delta-sigma modulation, which controls every 1 cycle, the fine control like the phase-angle firing system is possible.Setting unit (option)Display of various parameters, voltage/current/ power and change of the feedback system are possible.Various protections functions built-inThe thyristor element is protected by melting of the rapid fuse for short-circuit of load, and by gate-off for over-current. For models with a cooling fan built-in, alarm is activated and output is stopped for abnormal heat-sink temperature.Self-diagnosis function built-inThe self-diagnosis function is built in for abnormal operation, abnormal thyristor element and abnormal power supply.

Syinco Technologies Logo
   Syinco Technologies

Fno.B-313, Pno.1 and 7, Ace Ajanta Aprt, Fathullaguda, Rangareddy, Telangana, 500068

Send your enquiry to supplier

s

Related Products

Fotek Thyristor

₹ 15,000

Aux. Power Supply : 220VAC ±20%
Availability : In Stock
Brand : Fotek
Control Method : Zero cross control or phase angle control selectable ;  Excluding EPS2- & TPS2-

AYKAY ELECTRONICS, East Delhi, Delhi

Thyristor Power Regulator, SMD

Country of Origin : Made in India
Material : MS
Mounting Type : SMD
Phase : Single Phase

RADIX ELECTROSYSTEMS PVT. LTD., Mumbai, Maharashtra

JW Series Three Phase Thyristor Regulator

₹ 7,200

Applicable load : Resistive load, inductive load,density 1.2 T or lower are recommended)
Availability : In Stock
Control input signal : 4 to 20mA DC( input resistance is approx. 100 Ohm)
Control system : Phase angle firing system and zero-crossing firing system

Syinco Technologies, fathulguda, Telangana

Customer Reviews

Submit your Reviews

Best Selling Products from Syinco Technologies

KR2S Series Graphic Recorder

Additional memory : CF card (Upto 8GB), USB memory stick (Upto 8GB)
Alarm settings : : AND/OR selectable
Alarm Setups : Up to 4 alarms can be programmed per channel
Alarm types : Upper limit, lower limit, differential higher limit, differential lower limit

On-Line Infrared Radiation Thermometer

Accuracy rating : 200 degree C or less +/-2 degree C 200 degree C or more +/-1% of measuring value
Analog output : 4 to 20mA DC isolated outputOutput scaling Programmable in measuring range
Availability : In Stock
Element : PE

AH Series Type Digital Radiation Thermometers

Availability : In Stock
Collimation : Direct viewing finder
Detectors : Silicon
Display : LCD 4 digits display (in the finder and on the panel board)

ESC Series Scanning Type Radiation Thermometer

  : Kiln shell hot spot monitoring (Zone peak temperature graph, thermal-image display, historical display, report output)
Accuracy rating : Less than 400 degree C +/-4 degree C
Allowable voltage fluctuation : +10% to 15% of rated value
Availability : In Stock

Fixed Point Black Body Furnace

Availability : In Stock
Cabity Material : Graphite 5%ash
Cabity Size : 8 mm x 48 mm and with iris 3mm or 6mm
Crucible Size : 40 mm x 70 mm

Thermoelectric Conversion Efficiency Evaluation System

Availability : In Stock
Measurement : Power generation,heat flow and thermoelectric conversion efficiency
Measuring atmosphere : Atmosphere
Sample size : 40mm (square)

Power Generation Efficiency Characteristics Evaluation System

Availability : In Stock
Measurement : Power generation heat flow and thermoelectric conversion efficiency
Measuring atmosphere : Atmosphere,Inert gas
Sample size : 40mm (square)

EH3000 Series Analog Recorder

Ambient humidity : 20 to 80%RH (no dew condensation)
Ambient temperature : 0 to 50 Degree C
Availability : In Stock
Chart paper : Fanfold type, effective chart width 180mm, total width 200mm, total length 20m

TP-S Easy Thermo Imaging Sensor

Accuracy rating : +/-2% of measured value or +/- 3 degree C, whichever is greater
Auto power OFF : Approx. 5 min.
Availability : In Stock
Battery : Approx. 2 hr. (when using "Eneloop" or rechargeable NiMH battery)

EL3000 Series Analog Recorder

Alarm deadband : 0.4% of input span
Alarm output : 1a contact and 2 outputs (common)
Alarm programming : Individual setting for higher and lower-limit value
Alarm relay : Mechanical relay 1a contact, 2 outputs (common)

Ask a Question