Home » Testing & Measuring Equipments » Dyne Test Pen » Surface Energy Pen - Non-Toxic Ink (22-56 Dyne)

Surface Energy Pen - Non-Toxic Ink (22-56 Dyne)
Surface Energy Pen - Non-Toxic Ink (22-56 Dyne)
Surface Energy Pen - Non-Toxic Ink (22-56 Dyne)
Surface Energy Pen - Non-Toxic Ink (22-56 Dyne)
Product Video

Surface Energy Pen - Non-Toxic Ink (22-56 Dyne)

Product Specifications

Color Pink
material PVC
Automation Grade Manual
Availability In Stock
Brand Nd Industry
Country of Origin Made in India
Dyne level 22-56 dyne
Features Dyen Pen
Ink type Non toxic
Model Name/Number Dyne Test Pen
Pack size 1 pen
Type Of Testing Machines Dyne Testing
Usage/Application Measurement of a Surface Energy

GST No - 07EJAPK0298B1ZI | Member since 2025

C-11, GALI NO.37 B-2 BLK MAHAVIR ENCLAVE PART-III, UTTAM NAGAR , NEW DELHI, West 110059, Delhi, 110059

Looking for the latest Surface Energy Pen - Non-Toxic Ink (22-56 Dyne) price in 110059? Nd Industry, one of 110059's best Surface Energy Pen - Non-Toxic Ink (22-56 Dyne) sellers & manufacturers, off Read More...

   Qty  

Product Details

Dyne Level Measurement TECHNICAL INSTRUCTION ON HOW TO USE SURFACE TENSION / WET ABILITY TESTEROBJECTIVE OF TEST Wetting test as measured by this test show treatment level achieved by the surface of plastic film or substrate, which has been treated electrically or other means [or wet ability of non treated surface] to get satisfactory print or coating adhesion or anchoring This quality control test, is highly recommended for printing Coating and plastic blow molding industries Each test fluid gives an accurate means of surface tension level in terms of dynes/cms when applied to the surface to be tested  Test procedure Lay the specimen to be tested on a clean flat surface with treated side on the top transparent films should be kept on the top of white paper for better visibility of marking spread the test fluid or ink from the felt tip of test pen lightly over an area of 7 cms² of the test specimen (i.e. strip of 7 cams x 1cms). Note time taken for continuous film on ink to break into droplets. And not peripheral shrinkage. (border shrinkage ). Wetting is satisfactory or adequate ,when a continuous film of test fluid remains intact 3 seconds or more on the substrate to be tested .breaking of the ink film into droplets, in less than 3 seconds indicate a lack of wetting and a lower numbered test fluid to be tried. if the ink film remains intact for more than 3 seconds . The surface tension of this ink in dynes/cm "wetting tension" and these values are already marked on each of these pens/bottles. Please note that observations of the liquid film behavior should be made in the center of the liquid film. Shrinkage of the liquid film on the edges of the applied ink does not necessarily indicate a lack of wetting. Breaking of liquid film into droplets within 2 seconds, indicate lack of wetting this is especially true for substrate having treatment level above - 40 dynes cams ² Some experience with this will give excellent insight, to enable an accurate reading to be made. Extreme care must be ensure the film or substrate is not touched or contaminated in the area of lest. It is recommended that when testing is done during the production, the test fluid or ink to be applied across the full web width. QUALITATIVE RATINGS OF TREATMENT LEVEL OR WETTABILITY     Sr. No.Treatment level  in Dynes/cmExpected quality rating in terms of print or coating Adhesion / anchorine 1Below  32 Very poor printing or coating adhesion. 2 34Poor printing or coating adhesio 3 36Fairly good printing or coating adhesion. 4 38Good printing or coating adhesion. 5 40Very good printing or coating adhesion.6 Special instructions to avoid erroneous readings:   This is a delicate test, users should observe following instructions carefully otherwise the test result will be erratic/inconclusive or users may conclude that the TESTER is faulty. Erratic of inconclusive readings are observed under following testing conditions : Inconsistent (corona) treatment on the substrate may result in erratic readings. Loss of treatment or surface wetting tension due to repeated winding/unwinding of the material or due to friction on the machine may give erratic readings. Contamination due to dust or frequent handling of the treated material may also give erratic or inconclusive results. Therefore it is advisable to perform  test on fresh (untouched) samples. Insufficient fluid (test ink) in the working pens, insufficient fluid at the tips of the pens. Resulting in error. Therefore if testing is done after a long gap,

Nd Industry Logo
   Nd Industry

C-11, GALI NO.37 B-2 BLK MAHAVIR ENCLAVE PART-III, UTTAM NAGAR , NEW DELHI, West 110059, Delhi, 110059

Send your enquiry to supplier

s

Related Products

Automotive Brake Liquid Quick Test Pen

₹ 5,000

Automation Grade : Automatic
Availability : In Stock
Brand : JET AGE
Model Name/Number : JET 7701

Jet Age Garage Equipments, Delhi

Corona Dyne Test Pen

₹ 300

Color : Blue, Green, Yellow, etc
Dyne Value : 36, 40, 44, 48, 52, 56 Dynes/cm (mN/m)
Length : 2 Inch
Peripheral Shrinkage : 4 Sec

Konika Transglobal, New Delhi, Delhi

Dyne Test Pen (22-56 Dyne Level)

₹ 449

Availability : In Stock
Color : Pink
Country of Origin : Made in India
Dyne level : 22-56

Nd Industry, 110059, Delhi

TV Yellow and Red Fix it Pro Scratch Pen, Packaging Type: Box

₹ 100

Brand : TV
Color : Yellow and Red
Country of Origin : Made in India
Packaging Type : Box

Shiv Darshan Sansthan, New Delhi, Delhi

Dyne Test Disposable Pen

₹ 500

Availability : In Stock
Brand : Prevtise
Color : Blue
Dyne Value : 38 And 44

PREVTISE TECHNOLOGIES, New Delhi, Delhi

Manual Dyne Pen (Treatment Checking Pen )

₹ 400

Automation Grade : Manual
Availability : In Stock
Brand : In trade group
Country of Origin : Made in India

IN Trades Group, Delhi

Blue Dyne Fluid for Metal Cleanliness Test

₹ 21,000

Brand : ACCU DYNE TEST
Color : BLUE
Features : Narrow Mouth Ink Bottle
material : Blue Dyne Solution

Arham Scientific Co., Mumbai, Maharashtra

Customer Reviews

Submit your Reviews

Best Selling Products from Nd Industry

Heat Sealing Tape (50mm x 10m) - 280°C Temperature Resistance

₹ 358

Availability : In Stock
Brand : Nd Industry
Color : Brown
Tape Length : 10 m

SS Ring Handle Zahn Cups 1 to 5

₹ 2,499

Availability : In Stock
Brand : Nd Industry
Color : Sliver
Country of Origin : Made in India

Magnetic Powder Brake - 6 Nm Torque

₹ 28,500

Availability : In Stock
Country of Origin : Made in India
Material : Cast Iron
Packaging Type : Cartoon

PTFE Coated Fiberglass Fabric Cloth (Brown, 0.08 mm)

₹ 499 / Square Meter

Availability : In Stock
Base Fabric : Fiberglass
Brand : Nd Industry
Coating Type : PVC Coated

Nd Industry Flexo Anilox Cleaner For Flexo Gravure Printing

₹ 2,199

Application Type : Flexo Gravure Printing
Application : Industrial
Availability : In Stock
Brand : Nd Industry

Ceram Clean ll, Packaging Type: Bottle, For Industrial

₹ 6,500

Availability : In Stock
brand : harper
Form : liquid
Packaging Size : 500ml

Cast Iron 4 Inch Flanged NRV Valve for Air (PN 10)

₹ 9,550

Availability : In Stock
Country of Origin : Made in India
End Connection : Flanged
Material : Cast Iron

Dyne Test Pen (22-56 Dyne Level)

₹ 449

Availability : In Stock
Color : Pink
Country of Origin : Made in India
Dyne level : 22-56

Dyne Test Pen (22-56 Dyne) - Non-Toxic Ink

₹ 450

Availability : In Stock
Brand : ND INDUSTRY
Color : Pink
Country of Origin : Made in India

Zahn Cup 2 Stainless Steel Ring Handle

₹ 2,500

Availability : In Stock
Brand : Nd Industry
Country of Origin : Made in India
Cup Number : 1 to 5

Ask a Question

Find Best Price for