Home » Lab Instrument » Insulation Tester » Vorimeter SL 5880 Insulation Monitor Device

Vorimeter SL 5880 Insulation Monitor Device
Vorimeter SL 5880 Insulation Monitor Device

Vorimeter SL 5880 Insulation Monitor Device

₹ 13,500 Get Latest Price

Product Specifications

Brand Vorimeter
Auxiliary voltage AC,DC
Brand Vorimeter
Earth fault indicator Yes
Enclosure design Switch cabinet
Frequency 50 Hz
IMD type AC
Model Name/Number SL 5880
Nominal voltage IT system AC 0 - 500 V
Response value type Adjustable
Width 35mm

GST No - 09ABBFA4128K1ZH | Member since 2026

KH. NO. 522, GURUDWARA ROAD, PATEL NAGAR, GHAZIABAD, Ghaziabad, Uttar Pradesh, 201001

Vorimeter SL 5880 Insulation Monitor Device Read More...

   Qty  

Product Details

Product description Monitoring of insulation resistance of ungrounded voltage systems to earth.IL/SL 5880/200 can also be used to monitor standby devices for earth fault, e.g. motor windings of devices that have to function in the case of emergency.IL/SL 5880/300 according to DIN VDE 0100-551 to monitor mobile generator systemsOther resistance monitoring applications.For industrial and railway applicationsFeaturesAccording to IEC/EN 61557-8For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 10000 HzAdjustable tripping value RAL of 5 ... 100 kΩ or 10 ... 500 kΩMonitors also disconnected voltage systemsDe-energized on tripAuxiliary voltage Measuring Circuit and output contacts are galvanically separatedManual and auto resetWith test and reset buttonConnections of external test and reset buttons possibleLED indicators for operation and alarm2 changeover contactsIL/SL 5880/200 with additional prewarning- adjustable prewarning value 10 kΩ ... 5 MΩ- output function programmableVariant IL/SL 5880/300 according to DIN VDE 0100-551 for mobile generator sets available4 models available:IL 5880, IP 5880: 61 mm deep with terminals near to the bottomto be mounted in consumer units or industrial distribution systems according to DIN 43 880SL 5880, SP 5880: 98 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ductsDIN rail or screw mounting35 mm widthFunctions :The device is connected to the supply via terminals A1-A2. The unit can either be supplied from the monitored voltage system or from an sepa-rate auxiliary supply. Terminal L is connected to the monitored voltage and PE to earth. If the insulation resistance RE drops below the adjusted alarm value RAL the red LED goes on and the output relay switches off (de-energized on trip). If the unit is on auto reset (bridge between LT1-LT2) and the insulation resistance gets better (RE rises), the insulation monitor switches on again with a certain hysteresis and the red LED goes off. Without the bridge between LT1-LT2 the Insulation monitor remains in faulty state even if the insulation resistance is back to normal. (In order to achieve failure storage, the voltage system showing a fault must not be switched off too fast after detection of the failure, see notes). The reset is done by pressing the internal or external reset button or by disconnecting the auxiliary supply. By activating the "Test" button an insulation failure can be simulated to test the function of the unit.The variants IL/SL 5880.12/200 have a second setting range with a higher resistance up to 5 M??? (Potentiometer RVW). This setting value can be used for pre-warning with relay output, by positioning the lower setting switch to "AL 11-12-14; VW 21-22-24".If the higher setting range should be used only, the setting switch is put in position "VW 2u" and both contacts react only to the higher setting.If the lower setting range should be used only, the setting switch is put in position "AL 2u" and both contacts react only to the lower setting.When set to manual reset the latching is active on both settings RAL and RVW. Therefore it is possible in the case of a short insulation decrease (Switch position AL 11-12-14; VW 21-22-24), to pass the warning signal to a PLC while the main fault does not lead to a disconnection of the mains via the contacts 11-12-14

GST Number 09ABBFA4128K1ZH
Year of Establishment 2017
Nature of Business trader
Number of Employees 1 - 50
Turnover 3
Legal Status Partnership
AMPS CONTROLS & AUTOMATION Logo
   AMPS CONTROLS & AUTOMATION

KH. NO. 522, GURUDWARA ROAD, PATEL NAGAR, GHAZIABAD, Ghaziabad, Uttar Pradesh, 201001

Send your enquiry to supplier

s

Related Products

Industry LeaderIndustry Leader

Ramp Shoes Thermal Insulation Tester, For Industrial

₹ 2,85,000

Availability : In Stock
Brand : Ramp Impex Private Limited
Usage/Application : Industrial
Use : Footwear Testing

Ramp Impex Pvt Ltd, North Delhi, Delhi

200MV Meco Digital Insulation Tester, For Laboratory, Model Name/Number: Dit 99d

₹ 5,000

Availability : In Stock
Display Type : Digital
Model Name/Number : DIT 99D
Usage/Application : Laboratory

THE GLOBAL MARKETING, NAGPUR, Maharashtra

Customer Reviews

Submit your Reviews

Best Selling Products from AMPS CONTROLS & AUTOMATION

10A Idec Selector Switch(YW1S-33E20)

₹ 175

Base Material And Finishes : Metal
Country of Origin : Made in India
Current Rating : 10A
Number Of Switch Positions : 2

TDK Lambda RSEN-2020 Noise Filters

₹ 6,389

Material : Metal Sheet
Service Type : REMOVE NOISE
Type : industry
Usage/Application : EMI EMI FILTER

TDK Lambda RSHN-2020 Noise Filters

₹ 6,250

Material : Metal Sheet
Service Type : remove Noise from machine
Type : emi emc filter

Schaffner Emc FN3256H-25-33. Noise Filters

₹ 20,532

Filter Type : Three-Phase + Neutral EMC Filter
Frequency : 50/60 Hz Universal
Rated Current : 25A
Rated Voltage : 520 VAC

EMI EMC FILTER For the ULTRASOUND MACHINE

₹ 19,258

Color : Black
Conducted RF Noise suppression : CLEAR UTLRASOUND IMAGE
Country of Origin : Made in India
Maximum Continuous Operating Voltage : 1500 V DC

Emi Emc Filter MF423-4-2D-75A, Voltage rating: 440 V, Three phase

₹ 19,528

Attenuation : 50 dB
Compliance : CE
Connector type : Terminal block
Current rating : 75A

8 Pin Idec Sn2s-05d.

₹ 115

Current Rating : 10A
Dielectric Strength(Between Open Contacts) : 2000V AC for 1 minute
Maximum Tightening Torque : 0.8 N.m minimum (When tightening 0.5mm thick spade terminal tab)
Pin Type : 8 Pin

IDEC RJ2S-CL-D24 Power Relay

₹ 205

Coil Type : Non Latching
Electrical Life : 1 YAER
Number Of Poles : 2 Pole
Type : Industrial Relay

IDEC RU2S- D24 Power Relay

₹ 252

Coil Type : Non Latching
Electrical Life : 1 YEAR
Number Of Poles : 2 Pole
Type : Industrial Relay

Ask a Question

Find Best Price for