| Allowable signal source resistance thermocouple | 100 ohm or less |
| Allowable wire resistance | Resistance thermometer 10 ohm /1 wire or less |
| Availability | In Stock |
| Contact Capacity | Resistive load(240V AC 3A, 30V DC 3A) |
| Control interval | Approx. 0.1 seconds |
| Countermeasure against power failuer | Store setting contents in no-volatile memory. (Rewire 1 million times) |
| Display | Segment type LCD (LED backlight) |
| Inductive load | 240V AC 1.5A, 30V DV 1.5A |
| Input impedance | Thermocouple 1M ohm |
| Load resistance | 600 ohm or less |
| Maximum common mode voltage | 30V AC |
| Minimum load | 5V DC 10mA |
| Mounting | Panel mounting |
| Output specification | 4 to 20mA DC |
| Pulse cycle | 3 |
| Range | Thermocouple 16ranges, DC voltage 4ranges, Resistance thermometer 5ranges |
| Rated power supply frequency | 50/60Hz (+/-2%) |
| Rated power voltage | 100 to 240V AC (+/-10%) 24V DC |
| Reference junction compensation accuracy | +/-1.0 degree C (ambient temperature 23 degree C +/- 10 degree C) |
| Resistance thermometer measurement current | Approx. 1mA |
| Sampling rate | Approx. 0.1 seconds |
| SSR drive pulse output type | Approx. 1 to 180 seconds |
GST No - 36ADKPN4610N1Z8 | Member since 2026
Fno.B-313, Pno.1 and 7, Ace Ajanta Aprt, Fathullaguda, Rangareddy, Telangana, 500068
DB600 Series Digital Indicating Controller Read More...
Product Details
We have carved a niche amongst the most trusted names in this business, engaged in offering a comprehensive range of DB600 Series Digital Indicating Controller.Specification:Input type:ThermocoupleB, R, S, N, K, E, J, T, U, L, WRe5-WRe26, W-WRe26, Platinel II, PtRh4--PtRh20, Au-PtDC Voltage±20mV, ±100mV, ±5V, ±10VResistance thermometerPt100, JPt100, Pt50 Accuracy rating:±0.1% of FS ±1 digit of measuring range, For details, refer to "measuring ranges and accuracy ratings" in PS sheet Burnout:Upper limit burnout is provided for thermocouple, resistance thermometer and DC voltage (20mA)only as standard.Output 1 produces PV abnormal output and output 2 is fixed to 0% when burnout occurs.Upper limit alarm event is output Features:Excellent control performance:PID control algorithm and Z control algorithm are selectable according to the application.PID control algorithm: Conventional control methodZ control algorithm: Our new algorithm (patent pending) which has evolved the PID control method. Especially, the effect can be expected such as overshoot suppression and speedy recovery in the event of disturbance control (during opening and closing of the electric furnace). Large easy-to-view 5-digit 11 segments display:Process value (PV) and set value (SV) are displayed by large easy-to-view 5-digit display indicators. The resolution of 0.1°C is enabled high-definition and highly sophisticated. Operability inheriting previous models:The controller inherits the setting screen and the settings screen adopting the LCD (liquid-crystal-display) which has been familiarized for long time. Furthermore, the screens have become high-definition and highly sophisticated. 24V power supply voltage type available:The power supply voltage 24V (AC/DC) type, which is advantageous in respect of safe, is available. Various operating status in one glance:Operating conditionSetting value ramp (option for program model)Analog bar output Universal input:Various measurement ranges of DC voltage (up to maximum 10V) inputs, DC current input, thermocouple inputs and resistance thermometer inputs have been built-in. Program Operation (option):Set 4 patterns, 12 steps.Confirming to international safety standards and European directives (CE) (conformity pending)The controller is in conformity with European directives (CE), and is UL and c-UL approved. Engineering software (Standard attached):By connecting to PC with exclusive USB engineering cable (RZ-EC3) (sold separately), you can load/save parameter data and acquisition.
Fno.B-313, Pno.1 and 7, Ace Ajanta Aprt, Fathullaguda, Rangareddy, Telangana, 500068
Send your enquiry to supplier
Related Products
Proportional/On-Off NIKROM TC K81 Temperature Controller
₹ 1,250
| Accuracy : 2 |
| Control output Type : Relay/SSR |
| Control Type : Proportional/On-Off |
| Country of Origin : Made in India |
Magicpack Automations Private Limited, Medchal Malkajgiri, Telangana
₹ 700
| Availability : In Stock |
| Brand : Indian |
| Color : White |
| Country of Origin : Made in India |
Digital Refrigerator Temperature Controller
₹ 950
| Control Type : On-Off |
| Display Type : Digital |
| model : Digital Refrigerator Temperature Controller |
| Power : 100 to 240 VAC |
1 A Motor Pal ECU _CV93501-04 Speed Controller, For Industrial
₹ 10,000
| Automation Grade : Automatic |
| Availability : In Stock |
| Certifications : CE |
| Country of Origin : Made in India |
₹ 5,000
| Availability : In Stock |
| Brand : Dixell |
| Control Type : On/Off |
| Dimensions : 0.8x16x46 mm |
₹ 12,000
| Availability : In Stock |
| Brand : Clivet |
| Control Type : On/Off |
| Display Type : Digital |
Wani Electricals and engineering, srinagar, Jammu and Kashmir
Digital Temperature and Timer Controller, 90-270V
₹ 700
| Enclosure Material : Plastic |
| Frequency : 50 - 60 Hz |
| Operating Ambient Temp : 0 - 55 degree |
| Pack Type : Box |
Digital Temperature Controller
₹ 3,000
| Application Area : for Plastic Industry |
| Availability : In Stock |
| Control Type : PID |
| Display Size : 48*48 mm |
TC-333 Digital Temperature Controller
₹ 1,150
| Accuracy : 99% |
| Control output Type : Relay |
| Material : Body |
| model : TC-333 Digital Temperature Controller |
₹ 50,000
| model : TT0-2005 |
| Pump Power (kW) : 0.5 kW |
| Temperature Range : 0-200 Deg C |
| Transfer Medium : Oil |
Customer Reviews
Submit your Reviews
Best Selling Products from Syinco Technologies
| Additional memory : CF card (Upto 8GB), USB memory stick (Upto 8GB) |
| Alarm settings : : AND/OR selectable |
| Alarm Setups : Up to 4 alarms can be programmed per channel |
| Alarm types : Upper limit, lower limit, differential higher limit, differential lower limit |
On-Line Infrared Radiation Thermometer
| Accuracy rating : 200 degree C or less +/-2 degree C 200 degree C or more +/-1% of measuring value |
| Analog output : 4 to 20mA DC isolated outputOutput scaling Programmable in measuring range |
| Availability : In Stock |
| Element : PE |
AH Series Type Digital Radiation Thermometers
| Availability : In Stock |
| Collimation : Direct viewing finder |
| Detectors : Silicon |
| Display : LCD 4 digits display (in the finder and on the panel board) |
ESC Series Scanning Type Radiation Thermometer
| : Kiln shell hot spot monitoring (Zone peak temperature graph, thermal-image display, historical display, report output) |
| Accuracy rating : Less than 400 degree C +/-4 degree C |
| Allowable voltage fluctuation : +10% to 15% of rated value |
| Availability : In Stock |
Fixed Point Black Body Furnace
| Availability : In Stock |
| Cabity Material : Graphite 5%ash |
| Cabity Size : 8 mm x 48 mm and with iris 3mm or 6mm |
| Crucible Size : 40 mm x 70 mm |
Thermoelectric Conversion Efficiency Evaluation System
| Availability : In Stock |
| Measurement : Power generation,heat flow and thermoelectric conversion efficiency |
| Measuring atmosphere : Atmosphere |
| Sample size : 40mm (square) |
Power Generation Efficiency Characteristics Evaluation System
| Availability : In Stock |
| Measurement : Power generation heat flow and thermoelectric conversion efficiency |
| Measuring atmosphere : Atmosphere,Inert gas |
| Sample size : 40mm (square) |
| Ambient humidity : 20 to 80%RH (no dew condensation) |
| Ambient temperature : 0 to 50 Degree C |
| Availability : In Stock |
| Chart paper : Fanfold type, effective chart width 180mm, total width 200mm, total length 20m |
TP-S Easy Thermo Imaging Sensor
| Accuracy rating : +/-2% of measured value or +/- 3 degree C, whichever is greater |
| Auto power OFF : Approx. 5 min. |
| Availability : In Stock |
| Battery : Approx. 2 hr. (when using "Eneloop" or rechargeable NiMH battery) |
| Alarm deadband : 0.4% of input span |
| Alarm output : 1a contact and 2 outputs (common) |
| Alarm programming : Individual setting for higher and lower-limit value |
| Alarm relay : Mechanical relay 1a contact, 2 outputs (common) |