Product Specifications
| Alarm deadband | 0.1 to 100 degree C |
| Alarm output | Open collector 24VDC 0.1A (maximum) |
| Alarm point | 1 point |
| Allowable signal source resistance | Thermocouple input 100 ohm or lower |
| Anti reset windup | Automatic |
| Auto tuning | Standard (Manual setting of PID constants enabled) |
| Availability | In Stock |
| Burnout | Up scale |
| Control cycle time | Approx. 0.25 second |
| Control gap | 0.1 to 100.0 degree C (2-position control only) |
| Control setpoint | 2 sets switching, 4-digit setting |
| Control system | PID (2-position control is available. |
| Display | 4-digit LED |
| Display contents | PV or SV switching, Parameter item |
| E | 0 to 1500°F |
| Input shift | -100.0 to 100.0 degree C |
| Input signal | Thermocouple K, N, J, E, Platinel II,Resistance thermometer Pt100, JPt100 |
| Input signals | Measuring ranges |
| Installation | Panel installation |
| J | 0 to 1000°C |
| JPt100 | -199.9 to 500.0°C |
| N | 0 to 1300°C |
| Platinel II | 0 to 1390°C |
| Power Consumption | Maximum about 5VA |
| Power voltage | 100V to 240VAC 50/60Hz universal power supply |
| Resistance thermometer input | 10ohm or lower per wire |
| Sampling cycle | About 0.25 second |
| Weight | About 100g |
| Working humidity range | 35 to 85%RH (no dew condensation) |
| Working temperature range | -10 to 50 degree c |
GST No - 36ADKPN4610N1Z8 | Member since 2026
Fno.B-313, Pno.1 and 7, Ace Ajanta Aprt, Fathullaguda, Rangareddy, Telangana, 500068
LT110 Series Digital Indicating Controller, Maximum About 5VA Read More...
Product Details
Measuring range:Input signalsMeasuring rangesThermocouplesK0 to 1370°CE0 to 1500°FJ0 to 1000°CPlatinel II0 to 1390°CN0 to 1300°CResistance thermometersPt100-199.9 to 850.0°C-200 to 850°CJPt100-199.9 to 500.0°C-200 to 500°C Features:Compact, lightweight and space-saving type for downsizing equipment or panel boardMulti-input of thermocouples and resistance thermometersConformance to CEFront panel conforming to IP65 (IEC) water and dust protection
Fno.B-313, Pno.1 and 7, Ace Ajanta Aprt, Fathullaguda, Rangareddy, Telangana, 500068
Send your enquiry to supplier
Related Products
Proportional/On-Off NIKROM TC K81 Temperature Controller
₹ 1,250
| Accuracy : 2 |
| Control output Type : Relay/SSR |
| Control Type : Proportional/On-Off |
| Country of Origin : Made in India |
Magicpack Automations Private Limited, Medchal Malkajgiri, Telangana
Digital Temperature Controller
₹
350
950
| Control Type : IoT BASED |
| Input Type : Sensor |
| model : BPE-THC-2001 |
| Size : Compact |
IMPORTED On-Off Temperature Controller
₹ 400
| Availability : In Stock |
| Brand : IMPORTED |
| Control output Type : Relay |
| Control Type : On-Off |
₹ 25,000
| Country of Origin : Made in India |
| Usage/Application : Temperature Measurement |
Microprocessor Based Temperature Controller
₹ 13,900
| Accuracy : 0.2 ppm |
| Availability : In Stock |
| Brand : Globe Scientific Instruments |
| Dissolved Oxygen Accuracy : +-0.2 ppm |
DUAL CHANNEL INDICATOR CUM CONTROLLER
₹ 13,000
| Application Area : for Plastic Industry |
| Brand : Honeywell |
| Communication : RS485 |
| Control Outputs : 2 Outputs |
Henix Press To Set Temperature Controller
₹ 1,950
| Brand : Henix |
| Country of Origin : Made in India |
| Display Type : Digital |
| Material : Mild Steel |
Digital Temperature Controller With Dual Display, Relay
₹ 2,200
| Application Area : for Oven/ Furnace |
| Control Type : On/Off |
| Display Size : 96*96 mm |
| No of digits : 4+4 |
₹ 7,000
| Application : Automobile Industry |
| Availability : In Stock |
| Brand : Rosmerta |
| Price Range : Rs. 7000 to 14000 Per Piece |
Customer Reviews
Submit your Reviews
Best Selling Products from Syinco Technologies
| Additional memory : CF card (Upto 8GB), USB memory stick (Upto 8GB) |
| Alarm settings : : AND/OR selectable |
| Alarm Setups : Up to 4 alarms can be programmed per channel |
| Alarm types : Upper limit, lower limit, differential higher limit, differential lower limit |
On-Line Infrared Radiation Thermometer
| Accuracy rating : 200 degree C or less +/-2 degree C 200 degree C or more +/-1% of measuring value |
| Analog output : 4 to 20mA DC isolated outputOutput scaling Programmable in measuring range |
| Availability : In Stock |
| Element : PE |
AH Series Type Digital Radiation Thermometers
| Availability : In Stock |
| Collimation : Direct viewing finder |
| Detectors : Silicon |
| Display : LCD 4 digits display (in the finder and on the panel board) |
ESC Series Scanning Type Radiation Thermometer
| : Kiln shell hot spot monitoring (Zone peak temperature graph, thermal-image display, historical display, report output) |
| Accuracy rating : Less than 400 degree C +/-4 degree C |
| Allowable voltage fluctuation : +10% to 15% of rated value |
| Availability : In Stock |
Fixed Point Black Body Furnace
| Availability : In Stock |
| Cabity Material : Graphite 5%ash |
| Cabity Size : 8 mm x 48 mm and with iris 3mm or 6mm |
| Crucible Size : 40 mm x 70 mm |
Thermoelectric Conversion Efficiency Evaluation System
| Availability : In Stock |
| Measurement : Power generation,heat flow and thermoelectric conversion efficiency |
| Measuring atmosphere : Atmosphere |
| Sample size : 40mm (square) |
Power Generation Efficiency Characteristics Evaluation System
| Availability : In Stock |
| Measurement : Power generation heat flow and thermoelectric conversion efficiency |
| Measuring atmosphere : Atmosphere,Inert gas |
| Sample size : 40mm (square) |
| Ambient humidity : 20 to 80%RH (no dew condensation) |
| Ambient temperature : 0 to 50 Degree C |
| Availability : In Stock |
| Chart paper : Fanfold type, effective chart width 180mm, total width 200mm, total length 20m |
TP-S Easy Thermo Imaging Sensor
| Accuracy rating : +/-2% of measured value or +/- 3 degree C, whichever is greater |
| Auto power OFF : Approx. 5 min. |
| Availability : In Stock |
| Battery : Approx. 2 hr. (when using "Eneloop" or rechargeable NiMH battery) |
| Alarm deadband : 0.4% of input span |
| Alarm output : 1a contact and 2 outputs (common) |
| Alarm programming : Individual setting for higher and lower-limit value |
| Alarm relay : Mechanical relay 1a contact, 2 outputs (common) |